Old house or new, the same heat pump problem
Half the homes in Acadia Parish were built in 1980 or earlier, half in 1980 or later. A heat pump does not know the difference. A worn contactor, a failing capacitor, a dirty coil shows up on either one.

Takes about a minute. No obligation.
Half the homes in Acadia Parish were built in 1980 or earlier, half in 1980 or later. A heat pump does not know the difference. A worn contactor, a failing capacitor, a dirty coil shows up on either one.
A tech checking a mobile home, one of nearly one in five houses here, or a house built last year is looking for the same things. Nothing about Crowley's housing points to a stranger cause. Expect a straightforward diagnosis, not a search for something unusual.

NOAA nClimDiv, 1991–2020 normals
A heat pump losing refrigerant keeps running and keeps pulling current through a compressor that's working harder than it should.
Left alone, that compressor can overheat and seize, turning a refrigerant leak into a full compressor replacement.



Nothing about this area is especially hard on it. It's most likely the usual problem with the usual fix.
Find a contractorA diagnostic call starts outside at the unit, not at the thermostat. A tech checks for power at the disconnect, then watches what the outdoor fan and compressor actually do when the system calls for heat or cool. Gauges go on the refrigerant lines to read pressures. Low pressure points to a leak. High pressure points somewhere else, like a dirty coil or a failing fan motor. Electrical testing comes next. The capacitor gets checked for the charge it's supposed to hold. The contactor gets checked for pitting. The wiring gets checked for a loose connection that's worked itself free from vibration over time. Static readings alone don't tell the whole story, so a tech wants to see the system run through a full cycle if it can. A problem that only shows up once the system has been running a while, like a reversing valve that won't fully shift, never shows up on a system that's just been switched on and off again.
Look at the thermostat first. Make sure it's set to the mode you want and the batteries aren't dead. Check your breaker panel for a tripped breaker on either the indoor or outdoor unit. Look at the outdoor unit itself and clear away leaves, grass clippings or anything blocking the sides. Check the air filter and swap it if it's gray with dust. None of this needs a wrench, just eyes and hands.
Don't open the outdoor unit's cabinet or touch anything inside it. The capacitor in there holds a charge even with the power off. Don't add refrigerant yourself or try to find a leak. Don't keep flipping the breaker back on if it trips a second time, that usually means a short, not a fluke. If the outdoor fan is spinning but making a grinding or screeching noise, turn the system off at the thermostat and call. Running it that way can turn a motor bearing into a motor replacement.
A heat pump fails the same handful of ways no matter whose yard it sits in. The reversing valve is usually the first thing to suspect when heating and cooling seem to swap or blend, since it's the one part doing a job no furnace or straight AC has to do. Refrigerant leaks show up slow, at a weld joint or a fitting that's worked loose over years of the system expanding and contracting as it cycles. Outdoor fan motors wear out from sitting outside through everything the weather sends, and bearings go before the motor ever stops turning, which is why the grinding starts before the failure does. A dirty outdoor coil forces the whole system to work harder to move the same heat, and that strain finds whatever part was already weakest, often the compressor itself. None of these are unusual or hard to diagnose. They're just what happens to a machine that runs almost every day of the year.
A compressor failure is usually where repair stops making sense. The compressor is sealed, so fixing one means replacing it, and that part alone can cost close to what the rest of the system is worth. A reversing valve, a capacitor, a contactor, those are worth fixing almost every time, since the compressor and the rest of the system are still good underneath. Age matters less than what's already failed and what that failure did on its way down. A refrigerant leak caught early is a repair. The same leak ignored long enough to overheat the compressor is a different conversation. Ask what broke and what it was connected to before asking whether it's worth fixing.