Once a year is enough for a heat pump here, in fall or spring. The tech checks refrigerant charge, the outdoor coil, and the reversing valve that switches the system between heat and cool, a part that does not get much use but has to work when it's called on. About one in five homes in Iberville Parish is a mobile home, and if yours is one of them, mention it when you book. Line sets and electrical hookups on a manufactured home are often set up differently than on a site-built house, and the tech should know that going in. Half the homes in this parish were built in 1986 or earlier, so if your heat pump came with the house, a yearly visit is also a chance to ask the tech how much life it has left.
A dirty filter chokes airflow, and the heat pump has to work harder to push the same air through the house.
A clogged drain backs up and can shut the system down before it ever gets to the coil.
Cooling runs seven months here. March is the month to get ahead of it.
Cooling runs April through OctoberHeat runs November through MarchPower costs 11.73 cents a kWh statewide
Once a year still covers it, even with weather in the mix. Iberville Parish saw 14 damaging wind events between 2015 and 2024, and wind can fling debris into the outdoor unit or rock it loose on its pad. After a bad storm it's worth a quick look before the next heating or cooling push. That's not a reason to schedule more visits. The yearly tune-up still catches what matters, the charge, the coil, the valve. When the power drops out and comes back, a heat pump starts itself back up. Nothing to reset, nothing to relight.
A heat pump usually gives some warning before it quits. The outdoor unit may run longer than it used to, or shut off and start again more than it should. Air from the vents that used to feel warm in heating mode comes out lukewarm, and the thermostat never quite catches up. Frost on the outdoor coil that doesn't clear on its own is worth a look. So is any ice on the refrigerant lines. A hissing or bubbling near the unit can mean a refrigerant leak. If the reversing valve is slow to switch, you'll feel heat when you asked for cool, or cool when you asked for heat. A burning smell, a breaker that trips when the system starts, water pooling under the indoor unit, none of that waits for the next scheduled visit.
What the gauges show that your ears can't
A heat pump can sound fine and still be running low on charge. The only way to know is to connect gauges and check the pressure against what the system calls for. Too little refrigerant and the coil can frost over in cooling mode. Too much and the compressor runs hotter than it should and wears out early. Either way, the system keeps running while it quietly loses years.
The valve that barely moves
The reversing valve switches the system between heat and cool, and most of the time it just sits in one position. A valve that sticks from disuse won't show it until the day you need the other mode. A tune-up exercises it both ways, while a sticking valve is still a quick fix instead of a no-heat or no-cool call.
Between visits, the filter is the one thing worth your attention. Pull it out and hold it up to the light. If you can't see through it, it's past due, and a clogged filter makes the heat pump pull air through a smaller opening than it was built for. Keep the area around the outdoor unit clear too. Leaves, grass clippings, anything stacked against the cabinet blocks the airflow it needs to move heat in or out. Walk past it after a storm and check that nothing has blown against the coil or knocked the unit off level. Indoors, make sure nothing is piled on top of or in front of the vents and the indoor unit. Beyond that, leave the refrigerant, the valve and the electrical side to the tech who comes for the yearly visit.
A tune-up starts outside. The tech pulls the panel and checks the capacitor and contactor, the parts that get the compressor and fan running, since a weak capacitor is one of the most common reasons a heat pump struggles to start. The coil gets cleaned if it needs it, because a coil caked with dirt can't move heat the way a clean one does. Refrigerant charge gets checked against what the system calls for, not topped off by guess. Inside, the blower wheel gets a look, since one caked with dust pushes less air no matter how strong the motor is. The condensate drain gets cleared so it doesn't back up later. And the reversing valve gets cycled both directions, so if it's going to stick, it shows up now instead of on the first cold morning you need heat.